Slides: 2001 Slide Troubleshooting

Well, my saga and dislike of slides are continuing.

I have learned way too much about the 2001 version slide system.

From the bad board on a new HWH system to an unknown 40 amp fuse to the side delimitation to learning about the room in the sensor in a rest stop in Alabama.

The “room in” sensor is a black probe that hangs down from the block. If the slide comes in but will not pin, it is either the “room in” sensor or the 3500 psi sensor.

I adjusted the room in sensors and switched them to see which one was bad. It took a while but Mike Rogers over at MOT walked me through it yesterday.

If your slide comes in but will not pin, look at your lights underneath it will show either green or yellow and you can see if it is the sensing room in or not. If not, I had to remove the header and send the slide-out and then adjust the sensor as low as it can go and then it pinned. I hope it will pin when I run it out and back later today at home. John Sichenze 1001 U320 42′